So you may have to fish an additional four strand cable from the furnace room to the thermostat location photo 1.
Single stage furnace thermostat wiring.
A dual fuel system which is comprised of a gas furnace and a heat pump should be connected to a thermostat or control system that can accommodate the specific heating set points.
How to choose the right furnace thermostat.
The e and w2 hook ups are for the emergency heat relay and auxiliary heat control respectively.
Furthermore this thermostat wiring diagram is specifically for a system with two transformers your system likely only has one transformer as most typical residential systems only use a single transformer for control.
If not connect them in this manner.
Verify that the red wire is connected to the r terminal green wire to the g terminal and white wire to the w terminal.
The thermostat you purchased is designed for a single stage system such as an air conditioner and a single stage gas furnace.
Single stage hvac system thermostat source.
Cadet 16 7 amp 120 208 240 volt single pole electronic 7 day programmable wall thermostat in white.
Strip the brown thermostat wire back one half inch and connect it to the w2 terminal on the furnace.
If you have a two stage heat pump then you will also utilize terminal y2 for the second stage.
1 know your heating system.
The terminals are usually marked r and w.
Basically heating furnaces are of two types.
A basic two wire thermostat can be compared to a simple single pole switch that you will find throughout your home only instead of you turning the switch on and off as required a mechanical or electronic temperature controlled mechanism is the operator of the switch.
A two stage or variable speed system may only be operating at a single speed because the thermostat or control system doesn t allow for two stage wiring.
Conventional single stage systems will have one wire leading into w or w1 terminal for heating and one wire leading into y or y1 terminal for cooling.
One which is common is the single stage heating system and the other one is multi stage heating system.
A two stage thermostat may need more wires than your current programmable thermostat.
The new thermostat doesn t have these because it isn t designed for this type of installation.
The thermostat only kicks in the second stage if the furnace can t maintain 6 to 8 degrees per hour.
So that s the easiest way to identify single stage conventional hvac systems which would be furnace based or boiler based.